innovatouchDUO

Only equipment with 2 lasers in the same unit

Norms

Our equipment and our optical fibers comply with the regulatory requirements that each country requires. This quality excellence is the result of  our teams works, led with the strength and conviction to innovate and develop technologies which accompany different professionals in their evolution.

Hardware

Touch screen with motorized screen opening and closing, on-board computer, exclusive cooling system to optimize usage times, video camera input for video-microscope viewing and USB ports for data export.

Software

Friendly interface, patient data entry, data export to removable disk, work profiles storage, partial and total energy calculation, real-time digital clock counting during the treatment.

Design

Aesthetic and Innovative.  Ergonomically designed for use in the operating room and office, portable and easy to move.

Security

Power meter, fiber detector, medical grade power supplies, safety line filter, equipment certified according to standards IEC 60601-1 / IEC 60601-2-22.

Aplicaciones

The combination of two wavelengths extends the range of applications, allowing a more specific and selective treatment in your specialty. Greater absorption, less energy: better results.

Post-sale

Our after-sales service covers the entire continent to ensure your team is attended by specialized professionals. Depending on the complexity of the service, service may be provided in your office (on site) or in our laboratories.

Warranty

Our equipment come with a direct factory warranty. Permanent stock of units and accessories. Demand and commitment for those who trust us.

TECHNICAL DATA SHEET
LASER 1
LASER 2
Laser generator:
Diode In Ga As P.
Nd: YVO4 / LBO or Diode In Ga As P
Wavelength:
A choice
By choice *
Power over the tissue:
According to wavelength *
According to wavelength *
Exposure mode:
Single pulse / Repeat / continuous pulse
Repeat / continuous pulse.
Exposure time:
0.01 to 9.9 sec
0.01 to 0.20 sec
Fluence:
0 to 3800 J / cm
20 to 50 J / cm2
Interval time:
0.01 to 9.9 sec
0.01 to 0.15 sec
Frequency:
0.5 to 20 Hz
0.5 to 10 htz
Hand piece:
Variable focus 1, 2, 3, 4 and 5 mm in diameter
Fixed focus 1mm in diameter
Delivery system:
Fiber optic
Fiber optic.
Power:
110v (Alternating current), 5.5A, 50 / 60Hz.
230v (Alternating Current), 3.1A, 50 / 60Hz.
Consumption:
240W
240W
DIMENSIONS
Open:
48 x 36x 17.5
48 x 36x 17.5
Closed:
48 x 36x 17.5
48 x 36x 17.5
Weight:
20 kg.
20 kg.

Benefits

USB:  Two USB ports to connect peripherals and externally store session data.

Patient Data:  Simple patient data entry for archiving and subsequent follow-up.

Energy Calculation: In real time. Partial and total laser energy counting, based on power level and emission time.

3 Pulse Variables:  Single pulse (between 0.01 and 9.9 seconds). Repetitive pulse (between 0.01 and 9.9 seconds) and Continuous mode.

Touch Screen: Last generation interface. 12.1 touch screen without buttons or keys.

 

Benefits

USB:  Two USB ports to connect peripherals and externally store session data.

Patient Data:  Simple patient data entry for archiving and subsequent follow-up.

Energy Calculation: In real time. Partial and total laser energy counting, based on power level and emission time.

3 Pulse Variables:  Single pulse (between 0.01 and 9.9 seconds). Repetitive pulse (between 0.01 and 9.9 seconds) and Continuous mode.

Touch Screen: Last generation interface. 12.1 touch screen without buttons or keys.

 

Aplicaciones

The combination of two wavelengths extends the range of applications, allowing a more specific and selective treatment in your specialty. Greater absorption, less energy: better results.

 

Post-sale

Our after-sales service covers the entire continent to ensure your team is attended by specialized professionals. Depending on the complexity of the service, service may be provided in your office (on site) or in our laboratories.

 

Warranty

Our equipment come with a direct factory warranty. Permanent stock of units and accessories. Demand and commitment for those who trust us.

 

TECHNICAL DATA SHEET
LASER 1
LASER 2
Laser generator:
Diode In Ga As P.
Nd: YVO4 / LBO or Diode In Ga As P
Wavelength:
A choice
By choice *
Power over the tissue:
According to wavelength *
According to wavelength *
Exposure mode:
Single pulse / Repeat / continuous pulse
Repeat / continuous pulse.
Exposure time:
0.01 to 9.9 sec
0.01 to 0.20 sec
Fluence:
0 to 3800 J / cm
20 to 50 J / cm2
Interval time:
0.01 to 9.9 sec
0.01 to 0.15 sec
Frequency:
0.5 to 20 Hz
0.5 to 10 htz
Hand piece:
Variable focus 1, 2, 3, 4 and 5 mm in diameter
Fixed focus 1mm in diameter
Delivery system:
Fiber optic
Fiber optic.
Power:
110v (Alternating current), 5.5A, 50 / 60Hz.
230v (Alternating Current), 3.1A, 50 / 60Hz.
Consumption:
240W
240W
DIMENSIONS
Open:
48 x 36x 17.5
48 x 36x 17.5
Closed:
48 x 36x 17.5
48 x 36x 17.5
Weight:
20 kg.
20 kg.

12 + 5 =